Overview
The CY-FT07 Doppler flowmeter adopts the Doppler effect of sound waves propagating in fluid. It measures the fluid velocity by detecting the Doppler frequency shift generated when sound waves are scattered by fine particles and air bubbles in the fluid. The Doppler current meter features compact structure, no moving parts, long service life, simple operation and maintenance-free performance. It is widely used in sponge cities, water supply and drainage pipe networks, black and odorous water bodies, natural rivers, open channels, reservoirs, flow field analysis for scientific research, liquid level detection and other scenarios.
Technical Specifications
| Measured Variables | Flow velocity, liquid level, temperature |
| Accuracy | Flow velocity: 1.0%±0.01 m/s Liquid level: 0.2%±0.01 m Temperature: ±1°C |
| Resolution | Flow velocity: 1 mm/s Liquid level: 1 mm |
| Response Time | 10 s ~ 60 s Note: The smoothing factor can be set via communication protocol. A larger value means faster response of smoothed flow velocity. |
| Operating Frequency | 2 MHz |
| Transmit Power | 1 W |
| Protection Class | IP68 |
| Output Type | (4~20) mA, (0~5) V |
| Output Accuracy | 0.5% F.S |
| Communication | RS485, MODBUS |
| Power Supply | AC 220V; DC 24V |
| Power Consumption | ≤4 W |
| Measured Waterway Type | Pipes, channels, natural streams and rivers |